Full BodyPlethysmography

Overview

BodyBox is the perfect unit for:

  • Pulmonary function analysis with both children and adults
  • Ventilatory mechanics
  • Bronchodilatation studies and
  • Hypersensitivity research (challenge tests)

The cabin design is available as barometric or mixed mode (barometric and volumetric) with three sizes of cabin (The Standard – The Paediatric – The Super size).

The Paediatric is addressed to the junior subjects in the age range of 4 – 10 years old

Additionally the wheelchair access cabin has a twin door mode and a ramp to allow the subject to be tested in a wheelchair; the second door offering the facilities for the Physiologist to adjust and set the subject valve and prepare the subject; the extension to the front allowing the freedom of the lower body to be accommodated.

BodyBox series is incredibly easy to operate and patient comfort is given by:

  • An ergonomic chair
  • Comfortable box volume
  • The largest window area, all around vision
  • A double door version for wheelchair access
  • A simple quality procedure is provided with each equipment.

Advantages at a glance

  • Three internal volumes
  • Four models
  • Rapid stability
  • Automated BTPS correction during measurements
  • 30 ml Box calibration for highest sensitivity
  • Patient comfort
  • Single upgradable electronics module
  • Full integration to a comprehensive range of tests and products
  • Interchangeable paediatric flow transducers
  • Fully adjustable seat and patient valve to accommodate widest range of subjects
  • Can operate from any gas source for operation of pneumatic circuits, i.e. diffusion measurement cabins only need one gas supply
  • Optional integrated internal dosimeter for provocation testing in F/V and RAW modes
  • Total control of manufacturing and testing protocols
  • Widest range of test options

 

Options

screenshot-www medisoft be 2015-07-10 21-15-02

Specifications

Standard Model

  • Dim. (HxWxD)cm: 176x87x71
  • Weight: +/- 130 kg
  • Internal Volume: 960 liters
  • Patient Chair: Pneumatic adjustement
  • BodyBox closing door: Sturdy closing and internal handle
  • Power requirements: 230/115 VAC 50/60 Hz
  • Power consumption: 100 Va (module)
  • Warm-up time: 20 min (minimum)
  • Conform to electrical safety req. IEC60601/1

Double Door or XL Model

  • Dim. (HxWxD)cm: 179x120x83
  • Weight: +/- 150 kg
  • Internal Volume: 1250 liters
  • Patient Chair: Pneumatic adjustement
  • BodyBox closing door: Sturdy closing and internal handle
  • Power requirements: 230/115 VAC 50/60 Hz
  • Power consumption: 100 Va (module)
  • Warm-up time: 20 min (minimum)
  • Conform to electrical safety req. IEC60601/1

Paediatric Model

  • Dim. (HxWxD)cm: 140x66x55
  • Weight: +/- 105 kg
  • Internal Volume: 450 liters
  • Patient Chair: Pneumatic adjustement
  • BodyBox closing door: Sturdy closing and internal handle
  • Power requirements: 230/115 VAC 50/60 Hz
  • Power consumption: 100 Va (module)
  • Warm-up time: 20 min (minimum)
  • Conform to electrical safety req. IEC60601/1